TOFD is utilized for the rapid scanning of welds and the heat affected zones of in service components to detect their integrity. However, due to the software image utilized in TOFD, we normally recommend using Phased Array technology to image the defects once they have been detected using TOFD.
Time of Flight Diffraction (TOFD) is an advanced method of Ultrasonic inspection.
It is a very sensitive and accurate method for non-destructive testing of discontinuities in welded joints.
Time of Flight Diffraction (TOFD) ultrasonic test method can perform crack sizing very precisely and allow the owner to run the equipments or plants until the critical crack depth and length is not reached with a minimal risk of failure.
Conventional ultrasonic test method employs measuring of the amplitude of reflected signal which is relatively less reliable method of sizing defects because the amplitude strongly depends on the orientation of the crack.
Time of Flight Diffraction - TOFD ultrasonic test method uses the time of flight of an ultrasonic pulse to determine the position of a discontinuity of interest.
The Time of Flight Diffraction (TOFD) ultrasonic test system consists of a pair of probes placed on opposite sides of a weld.
One of the probes emits an ultrasonic pulse that is collected by the probe on the other side. In undamaged pipe, the signals picked up by the receiver probe are from two waves: one that travels along the surface and one that reflects off the far wall.
These ultrasonic waves are diffracted from the tip of the discontinuities, if present. The size of the discontinuity is calculated by measuring time of flight of the ultrasonic pulse.
Compared to conventional ultrasonic testing, Time of Flight Diffraction (TOFD) ultrasonic testing instruments and probes are complex and expensive and requires highly trained, skilled and experienced technicians.
WWOFI professionals are trained and experienced in Time of Flight Diffraction (TOFD) ultrasonic testing.